Waterproofing Integrity utilise a number of types of electronic leak detection with a view to being fit for purpose and benefits that each offers. Electronic Leak Detection is a testing method applied to many waterpoofing membranes as a method of checking for the continuity of the membrane. The thickness readings are obtained by measuring the time taken for the ultrasonic signal to propagate from the probe to the coating/substrate interface and back. Making QUALITY products was and still is our priority and continually Investing in the backbone of our company. While Durotech has its own testing laboratory, the Durotech range has also been externally tested as low VOC by an independent, nationally accredited Firm. At Durotech we make it our mission is to be at the front when choosing construction chemical products and solution


Implementing these standards requires a comprehensive understanding of waterproofing principles and a commitment to quality in every aspect of the design and installation process. These practices not only safeguard the structure against potential water damage but also contribute to the overall durability and safety of the building. Adequate drainage solutions are a fundamental aspect of any successful external waterproofing strategy, playing a critical role in managing water runoff and preventing accumulation. Addressing these vulnerabilities is essential for maintaining the waterproofing system’s integrity. Penetrations through the waterproofing membrane, such as those for pipes, cables, and other utilities, represent potential weak points where water ingress can occur.
This may seem like a simple concept, however the many applications and designs of the external areas of buildings – roofs, balconies, decks, planter boxes, etc… make this concept hugely complex. The system should be designed in advance of the works commencing and the application installed with care and detail to ensure absolute water tightness. All of the above factors must be considered, and the materials installed in a way that will not compromise the integrity of the waterproofing system. It is therefore very important to know the requirements of the intended waterproofing area & to ensure the materials are fit for the purpose they’re being installed onto. Independent Testing Australia Selecting the right waterproofing membrane is crucial for protecting your building against water damage and ensuring the safety and well-being of its occupants. By ensuring that your building has adequate waterproofing, you can help to protect your property and ensure that it remains safe and healthy for all occupant

SAA Approvals
Your trusted partner for precision testing, sustainability-driven solutions, and real-time insights. Accurate testing of materials’ mechanical properties and strength. Comprehensive inspections to ensure manufacturing quality and compliance. Aerial inspection services using high-precision drone technology. Intertek is an international lab testing and quality assurance service provider in more than 30 industries and has several branch offices in Australia.
The benefits of being a NATA accredited organisati


Wolfin Membranes Australia issues a single point warranty on both the materials and the workmanship / application. The application of Wolfin is fully controlled and inspected by Projex Group – this is why Wolfin outperforms other waterproofing systems. A reliable system of waterproofing to the external surfaces of a building is designed to prevent the ingress of water. As mentioned above, there are 5 main groups of waterproofing membrane systems and each of these groups require different approaches depending on a number of factors as well as the installation requirements. There are many significant factors that need to be considered with regards to the design and installation of the waterproofing membrane. The Australian Standard considers and sets out the requirements (based on scientific testing) of the material properties of different types of waterproofing membranes.
CSIRO / APAS Specification AP-S4003 Waterproofing Membranes For Wet Are

Our onsite team of technicians are highly trained in the use of state-of-the-art diagnostic equipment to provide quantitative reports on any waterproofing system, ensuring compliance with industry standard

For example, a membrane designed for under-tile use, is not likely to be appropriate for usage in a planter box, and a membrane designed for use in a planter box, is not likely to be appropriate for usage on an exposed roofto


The measured strain can be fitted with equations governing different mechanisms of creep, such as power law creep or diffusion creep (see creep for more information). Tensile testing of creep generally follows the same testing process as standard testing albeit generally at lower stresses to remain in the creep domain rather than plastic deformation. Tensile testing can be used to test creep in materials, a slow plastic deformation of the material from constant applied stresses over extended periods of time. When dealing with porous and soft materials, as electrospun nanofibrous membranes, the application of the above stress formula is problematic. For soft and porous materials, like electrospun nonwovens made of nanofibers, the specimen is usually a sample strip supported by a paper frame to favour its mounting on the machine and to avoid membrane damaging. Tensile strength is vital for crack bridging products as it measures the material’s resistance to breaking under tension.
Proce